The C850M Integrated Water Insoluble Matter Testing System is based on the principle of gravimetric method measurement and testing standards for chemical reagents, pharmacopoeias, and other relevant testing protocols. It is specifically designed for the detection of water insoluble matter in chemical reagents and pharmaceutical excipients.
Traceable Data
Safe & Compliant
Intelligent Control
The sample is dissolved in water, and the insoluble matter is filtered out. The residue is washed with water to completely separate it from the main sample. After drying, the weight of the insoluble matter is measured using the balance.
GB/T 9738 and other relevant standards for testing water insoluble matter in chemical reagents and pharmaceutical excipients.
Basic Applications | Chemical Reagents | Determination of water insoluble matter in various chemical reagents. |
Pharmaceutical Excipients | Determination of water insoluble matter in various pharmaceutical excipients. |
Table 1:Test Parameters Note2
Parameter\Model | C850M | |
Test Range | mg | 0.3~80,000 |
0.05~10,000(optional) | ||
Resolution | mg | 0.1 |
0.01(optional) | ||
Repeatability | mg | ±0.3 |
±0.05(optional) | ||
Temperature Range | ℃ | Room temperature~130 |
Temperature Fluctuation | ℃ | ±0.5 |
Extended Functions | 21 CFR Part11 | optional |
Computer system requirements for GMP | optional | |
Table 2:Technical Specifications
Test Stations | 12 |
Glass Filter Crucible Volume | 100mL Note 3 |
Glass Filter Crucible Pore Size | 5um~15um Note 3 |
Gas Specifications | Compressed air (gas source is provided by the user) |
Gas Source Pressure | ≥ 72.5 PSI / 500 kPa |
Port Size | Φ8 mm Polyurethane tube |
Instrument Mainframe Dimensions | 24.8” H x 41.3” W x 28.7” D (63cm× 105cm× 73cm) |
Power Supply | 120VAC±10% 60Hz / 220VAC±10% 50Hz |
Net Weight | 396Lbs(180kg) |
Table 3:Product Configuration
Standard Configuration | Instrument mainframe, including scale (0.1mg), electrical control module, reagent collection module, liquid cooling module, glass filter crucibles (12), Φ8 mm Polyurethane tube |
Optional Parts | Software, computer system requirements for GMP, 21 CFR Part11, air compressor (exhaust capacity > 200L/min), glass filter crucibles (100mL), scale (0.01mg), weight (50g) |
Note 1: The described product characteristics are subject to the specific annotation of the "Technical Parameters"table.
Note 2: The parameters in the table are measured in Labthink’s laboratory by professional operators as per requirements and conditions of the relevant laboratory environment standards
Note 3: The glass filtercrucible volume and pore size can be customized, but the test range may besubject to alteration.
Labthink is always dedicated to the innovation and improvement of product performance and functions. Therefore, technical specifications are subject to change without further notice. Labthink reserves the right of final interpretation and revision.
Need help or have a question? For more information on how Labthink can help your company profit through testing, please Click the button.